Background
In recent years, in response to global warming and climate change caused by greenhouse gas emissions,many countries have focused on promoting electric vehicles to replace traditional fuel vehicles. And the construction of charging piles is very important in the promotion of new energy vehicles.Therefore, a large number of charging pile projects have emerged around the world.
Project Overview
The company is a charging pile manufacturer located in South Korea, using our DC energy meter DJSF1352-RN to match their DC charging pile. After using it for a period of time, they’re very satisfied with the quality of our products.
DJSF1352-RN DC Energy Meter
Technical Parameter
Technical parameters |
Indicators |
||
Input |
Nominal value |
Voltage input range |
Current input |
DC 0-1000V See the physical wiring diagram |
Shunt:0-75mV; Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. |
||
Overload |
1.2 times rated (continuous); 2 times rated/1 second; |
||
Power consumption |
Voltage: ≤0.2VA, current ≤0.1VA |
||
Accuracy class |
Class 1 |
||
Function |
Display |
8-bit segment LCD screen (LCD) |
|
Communication Interface |
RS485, infrared |
||
Communication protocol |
Modbus-RTU,DL/T 645-2007 |
||
Switch |
Switch output |
2 Relay outputs, 2A/30VDC or 2A/250VA |
|
Switch input |
2 dry contact inputs |
||
Pulse output |
A second pulse output, a energy pulse output |
||
See the SYS->PLUS display in the meter menu setting For example: The meter displays 100, which is 100imp/kWH |
|||
Power Supply |
Voltage range |
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) |
|
Power consumption |
≤ 3W |
||
Power frequency withstand voltage |
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min |
||
Insulation resistance |
≥ 40M Ω |
||
Average barrier-free working hours |
≥50000h |
||
Environment |
Temperature |
Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+80℃ |
|
Humidity |
≤93%RH, no condensation, no corrosive gas |
||
Altitude |
≤2500m |
Acrel energy meters for charging pile
Item |
Shape |
Type |
Function |
Single Phase AC Energy Meter |
|
ADL10-E |
Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). |
|
ADL100-ET |
Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). energy pulse output; optional multi tariff. |
|
|
ADL200 |
Din rail mounted; single-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy, etc.; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
|
Three Phase AC Energy Meter |
|
ADL400 |
Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
|
ADL3000-E |
Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
|
DC Energy Meter |
|
PZ72(L)-DE |
Panel mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement support 75mV output of shunt, support 0-5V, 0-20mA output of hall; RS485(Modbus protocol) |
|
DJSF1352 |
Wall mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement supports 75mV output of shunt, supports 0-5V, 0-20mA output of hall; RS485(Modbus protocol) |
|
|
DJSF1352-RN |
Din-rail mounted, support optional two-channel DC voltage, current, power measurement; measure DC energy; direct connect voltage 0-1000V; current measurement support shunt 75mV output, support Hall sensor 0-5V, 0-20mA output; RS485 communication (Modbus protocol) |
|
Shunt |
|
AFL-T |
Common Specification: 300A/75mV |
Hall Sensor |
|
AHKC |
Common Specification: 1000A/5V |
Structure