AWT100 IoT Smart Gateway whth RS485 4G WiFi Ethernet Communication

                 

Function

                                

   

Parameter Name AWT100-4GHW AWT100-NB AWT100-LW
AWT100-LoRaHW
Working  frequency
4G LTE-FDD: B1 B2 B3 B4 B5 B7 B8 B12
B13 B18 B19 B20 B25 B26 B28
4G LTE-TDD: B38 B39 B40 B41
NB-IoT: H-FDD B1 B3 B8 B5 B20
LoRaWAN: 470MHz
LoRaWAN: 863~870MHz
LoRaWAN: 920~928MHz

LoRa: 460~510MHz

LoRa: 860~935MHz

Transmission rate
LTE-FDD
Maximum downlink rate 150Mbps
Maximum uplink rate 50Mbps
LTE-TDD
Maximum downlink rate130Mbps
Maximum uplink rate 35Mbps
CDMA
Maximum downlink rate 3.1Mbps
Maximum uplink rate 1.8Mbps
GSM
Maximum downlink rate 107Kbps
Maximum uplink rate 85.6Kbps
Maximum downlink
rate 25.2Kbps
Maximum uplink rate
15.62Kbps
LoRa 62.5kbps
LoRa 62.5kbps
Downlink RS485 Communication
Uplink 4G Communication
NB-IoT
Communication
LoRaWAN Communication
LoRa Communication
SIM card voltage  3V,1.8V /
Working current Static power:≤1W,Transient power consumption:≤3W
Static power: ≤0.5W, Transient power
Consumption:≤1W
Antenna interface 50Ω/SMA(Faucet)
Serial port type RS-485
Baud rate 4800bps、9600bps、19200bps、38400bps(default 9600bps)
Operating Voltage DC24V /AC/DC220V① 
Operating temperature -10℃~55℃
Storage temperature -40℃~85℃
Humidity range 0~95% Non-condensing
                               
                                          
Main Parameters

                                  

   

Parameter name AWT100-GPS AWT100-WiFiHW AWT100-CE AWT100-DP
Work
Positioning accuracy:
2.5-5m
Support 2.4G&5G frequency band
WiFi rate: 115200bps
Ethernet rate 10/100M adaptive Profibus address: 1~125. (Note)
Downlink RS485 Communication
Uplink GPS positioning WiFi wireless
Ethernet
communication
Profibus
communication
Working current
Static power consumption:≤1W,transient power consumption:≤3W
Static power
consumption:
≤0.5W,
transient power
consumption:
≤1W
Interface
 
50Ω/SMA(Faucet)
RJ45 DP9
Serial port type RS-485 Communication
Baud rate 4800bps、9600bps、19200bps、38400bps(Default 9600bps)
Operating Voltage DC24V or AC/DC220V①
Operating temperature  -10℃~55℃
Storage temperature -40℃~85℃
Humidity range 0~95% Non-condensing
 
Note:
①AC/DC220V power supply requires external AWT100-POW power supply module.
②Profibus communication rate: 9.6kbps, 19.2kbps, 45.45kbps, 93.75kbps, 187.5kbps, 500kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps. Data exchange length: total input length<=224 bytes, total output length<=224 bytes. The number of downstream instruments connected: 1~80.

        

                                

Share This Items :

Product Details

AWT100 wireless gateway communication terminal is a new wireless data acquisition device launched by Acrel.

The uplink communication includes 2G, 4G, NB, LoRa, LoRaWAN and other communication modes. The downlink interface provides a standard RS485 data interface, which can easily connect power meters and RTUs, PLC, industrial computers and other equipment, only need to complete the initial configuration, you can complete the data acquisition of MODBUS equipment.

At the same time AWT100 series wireless communication terminal uses a powerful micro-processing chip, with built-in watchdog technology, reliable performance stable.

Download

 

                 

Characteristics

       

Various Upstream Communication Methods

● 4G (Support Global Frequency Bands)

● WiFi

● LoRa

● LoRaWAN

● Ethernet

● NB-IoT

● ProfiBus-DP

● GPS

 

Collect Data from up to 30 Devices

 Downstream Communication: RS485

● Downstream Protocol: MODBUS-RTU

● Data acquisition of 5 register address fields each device

 

Easy Installation

 RJ45 Interface

● 35mm standard DIN Rail

 

Three Optional Power Supply

● DC 12V

● DC 24V

● AC/DC 220V→DC 5V (paired with AWT100-POW)

● 3 types of Power Supply can’t co-exist

                      

Dimension

 

                

Installation Instruction

 

     

     

Solution Structure

                         

   

Typical Connection

 

 

 IoT  Web&Mobile APP 

                                           

 Package

                                                                    

         

MINIMUM PACKAGE

 

MINIMUM PACKAGE

Package dimensions(1 PC)

130*150*170mm

Pakage Weight(1 PC)

0.218Kg

 

WHOLE BOX PACKAGE

 

Package dimensions(16 PCS)

295*220*145mm

Pakage Weight(16 PCS)

3.488kG

PRODUCT HS CODE

8543709990

Latest news

Application Analysis of Acrel Prepaid Energy Meter and Energy Management System

Energy Consumption Management System Solution

AM5-DB Low-voltage Automatic Switching Device for Backup Power Supply Application in Dongting Substation Project of Hebei Guanyi Rongxin Technology Company

Charging Pile Energy Management System Solution

Substation Operation and Maintenance Cloud Platform Solution

Acrel Energy Meter Application In Korea Charging Pile Manufacturer

Centralized Monitoring System Solution for Wind Farms

Good News! Congratulations to Acrel ADL3000-E Energy Meter for Obtaining The 1st Certificate of UL61010-2-030 Standard in China!

Warmly Welcome Malaysian Customers to Acrel for Technical Exchanges

Welcome to ENLIP EUROPE

Professional Service

Advanced Technology

Wireless Temperature Monitoring System Solution

Application of Intelligent Lighting Control System in Railway Station Building

Welcome to Middle East Energy 2024

Acrel Power Monitoring System Application in Pepsi Asia R&D Center

Analysis and application of unattended substation operation and maintenance cloud platform

IoT Remote Power Monitoring Solution

Application of Active Filters in Biopharmaceutical Industry

Acrel Wireless Temperature Sensor Application in South Africa

A brief discussion on the application and development of wireless network meters in the ubiquitous power Internet of Things

Application and product selection of electric power monitoring system in intelligent building

Precision distribution,multi circuits monitoring,railway transportation,leakage current

Acrel Wireless Temperature Measuring Product Application in Netherlands Substation

Acrel Energy Meter Application in Base Station in Indonesia

Acrel Hospital Isolated Power Supply Application in Malaysia

Acrel DC Energy Meter Application in Base Station in Indonesia

Excellent Quality

Welcome to HANNOVER MESSE 2024

Solar PV Energy Solution

Hydroelectric Power Plant Measurement Device Configuration Selection And Plant Power Management System

The Impact of Grid-connected Photovoltaic Power Generation on Power Quality and Solutions

Application of Hall Current Sensor in Battery Cabinet Monitoring

R & D Strength

Acrel at the 48th MIDDLE EAST ENERGY DUBAI 2023

Application of Wireless Temperature Measurement System in Coal Mine High Voltage Electrical Equipment

Precision distribution monitoring solution for IDC

en_USEnglish