AMC96L-E4/KC Three-phase Multi-function Panel Energy Meter

Function

   

   

Function Description&Value
Measurement

Three-phase AC kWh, kVarh, Active Power, Reactive Power, Forward&Reverse Power, Current, Voltage, Zero Sequence Voltage, Zero sequence Current, Voltage-phase Angle, Voltage&Current Unbalance, Power Factor,Harmonic, Frequency

Display

LCD display

Communication
(Optional)

RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 1200~38400 bps etc.

Alarm Output
(Optional)

1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC,

Used for high,low,unbalance alarm etc.

Analog Output
(Optional)

1~5V DC or 4~20mA DC

DI/DO Switching
(Optional)

DI (Digital input): 2-channel or 4-channel dry contact digital input with built in power supply

DO (Digital output): 2-channel digital output with NO relay contact. Capacity: 3A/30V DC,3A/250V AC

 

   

Main Parameters

             


Parameter Description&Value
Input
Rated Voltage AC Voltage Input: 400V or 660V AC L-L (via direct connetion); 100V AC L-L (via -/100V AC PTs)
Rated Current  AC Current Input: 5A AC or 1A AC (via -/5A AC or -/1A AC CTs)
Overload

Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second

Frequency 45~65Hz
Power Consumption

Power consumption of each current&voltage input circuit is less than 0.5VA

Measuring Accuracy
Voltage 0.2%
Current 0.2%
Active Power 0.5%
Reactive Power 1.0%
kWh 0.5%
kVarh 1.0%
Frequency ±0.05Hz
Harmonic ±1%
Power Supply
Voltage Range  85-265V AC/DC; 24V or 48V DC (±20%)
Power Consumption

≤10VA

Insulation resistance

≥ 100MΩ

Power frequency withstand voltage

Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min;

Between Power supply、switching output、Current Input、voltage Input AC 2 kV 1min;

Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min;

Share This Items :

Product Details

AMC series meters adopt AC sampling technology, which can measure the current ,voltage,power, power factor and electric energy parameters in the power grid separately.

It can set the magnification through the panel membrane switch. The meters have RS485 communication interface, adopt Modbus protocol; also can convert the power signal into a standard DC analog signal.

     
Download

 

    

     

Characteristics 

 

● Measurement: 3-phase AC kWh, kVarh, I, U, kW, kVar, Hz, cosφ and etc

● Accuracy: 1% (kWh); 0.5% (Active Power)
 Rated Voltage: 400V or 660V AC L-L (direct connect); 100V AC L-L (via PTs)
 Rated Current: 5A AC or 1A AC (via CTs)
● Power Supply: 85~265V AC/DC; 24V or 48V DC
● Communication: RS485 (MODBUS-RTU)
● SOE Funciton: Event&Demand&Extremum Record
● Harmonic Measurement: 2~31st and total Harmonic
● Analog Output: 4~20mA DC or 1~5V DC
● DI/DO Function: 2/4-channel DI&2-channel DO
● Standard&Certificate: CE Certificates

                                                         

                         

Front View

               

                  

Dimension  Unit:mm(in) 

    
   
              

         

                

Wiring

    
      

        

Network Structure 

 
         

         

        

Installation

   

 

         

Package 

     

    

MINIMUM PACKAGE

 

MINIMUM PAKAGE

Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.35Kg

 

WHOLE BOX PAKAGE

 

Package dimensions(36 PCS)

450*240*250mm

Pakage Weight(36 PCS)

13kG

PRODUCT HS CODE

9028301400

Latest news

Acrel Power Monitoring System Application in Pepsi Asia R&D Center

Welcome to ENLIP EUROPE

IoT Remote Power Monitoring Solution

A brief discussion on the application and development of wireless network meters in the ubiquitous power Internet of Things

Solar PV Energy Solution

Advanced Technology

Centralized Monitoring System Solution for Wind Farms

Acrel Energy Meter Application in Base Station in Indonesia

Good News! Congratulations to Acrel ADL3000-E Energy Meter for Obtaining The 1st Certificate of UL61010-2-030 Standard in China!

Application of Intelligent Lighting Control System in Railway Station Building

Welcome to Middle East Energy 2024

Application Analysis of Acrel Prepaid Energy Meter and Energy Management System

Wireless Temperature Monitoring System Solution

Acrel Wireless Temperature Measuring Product Application in Netherlands Substation

R & D Strength

Acrel DC Energy Meter Application in Base Station in Indonesia

AM5-DB Low-voltage Automatic Switching Device for Backup Power Supply Application in Dongting Substation Project of Hebei Guanyi Rongxin Technology Company

Acrel Energy Meter Application In Korea Charging Pile Manufacturer

Welcome to HANNOVER MESSE 2024

Energy Consumption Management System Solution

Analysis and application of unattended substation operation and maintenance cloud platform

Substation Operation and Maintenance Cloud Platform Solution

Charging Pile Energy Management System Solution

Warmly Welcome Malaysian Customers to Acrel for Technical Exchanges

The Impact of Grid-connected Photovoltaic Power Generation on Power Quality and Solutions

Professional Service

Precision distribution,multi circuits monitoring,railway transportation,leakage current

Application of Hall Current Sensor in Battery Cabinet Monitoring

Acrel Hospital Isolated Power Supply Application in Malaysia

Excellent Quality

Application of Active Filters in Biopharmaceutical Industry

Precision distribution monitoring solution for IDC

Application and product selection of electric power monitoring system in intelligent building

Acrel Wireless Temperature Sensor Application in South Africa

Application of Wireless Temperature Measurement System in Coal Mine High Voltage Electrical Equipment

Hydroelectric Power Plant Measurement Device Configuration Selection And Plant Power Management System

Acrel at the 48th MIDDLE EAST ENERGY DUBAI 2023

en_USEnglish